Excessive energy use
Unnecessary run hours, poor sequencing, excessive cycling, unsuitable setpoints or plant operating against demand.
Independent assessment of mechanical and electrical systems, operating conditions, energy performance and plant behaviour to identify waste, reliability concerns and practical improvement opportunities.
A Building Performance & M&E Audit reviews the operation, condition and interaction of relevant mechanical and electrical systems.
The purpose is to establish where performance may be falling short, what evidence supports that conclusion and which practical actions should be considered next.
The scope can be focused on a known concern or widened to examine connected systems where the cause is not yet clear.
Building problems often result from several operating, control or maintenance issues acting together.
Unnecessary run hours, poor sequencing, excessive cycling, unsuitable setpoints or plant operating against demand.
Incorrect temperatures, low flow, poor heat transfer, distribution problems or inadequate system response.
Repeated faults, short cycling, duty and standby issues, excessive wear or unsuitable operating conditions.
Plant, controls, pumps, valves and distribution systems failing to operate together as intended.
Equipment condition, filters, valves, sensors and recurring defects affecting system performance.
A lack of evidence about which issues require immediate action, further investigation or planned capital work.
The audit is not limited to one item of plant where the evidence indicates that connected systems are affecting performance.
The precise systems reviewed depend on the building, available information, access and agreed scope.
Boilers, heat exchangers, pumps, valves, heating circuits, temperatures, flow and sequencing.
Chillers, cooling circuits, pumps, coils, condenser systems, temperatures and operating strategy.
Air-handling units, fans, filters, dampers, coils, airflow and ventilation operating conditions.
Hydronic balancing, flow rates, differential pressure, temperature differentials and system water condition.
Plant enables, schedules, setpoints, interlocks, sensors, alarms, overrides and trend data.
Electrical measurements, motor operation, controls, distribution information and equipment condition where relevant.
The audit method is selected according to the question, systems, available information and level of investigation required.
The exact process depends on the agreed scope, but the core stages remain clear.
Discuss the building, systems, known issues, available records and required outcomes.
Examine available drawings, energy data, maintenance information and system records.
Review plant, controls and operating conditions using methods selected for the scope.
Compare observations, measurements and records to identify gaps and likely causes.
Present clear findings, recommended actions and further investigation where required.
Findings depend on the building and scope, but may include issues such as:
The audit is designed to help clients understand which actions may produce the greatest practical value.
Identify unnecessary plant operation, inefficient control and poor system response.
Focus attention on avoidable consumption, repeated faults and ineffective maintenance.
Identify conditions that may affect plant life, resilience and continuity of service.
Use evidence to distinguish operational changes, remedial work and longer-term capital needs.
The audit approach is informed by operational engineering experience across marine, offshore energy and building services, including renewables, BMS, HVAC and M&E systems.
That background supports a disciplined review of how connected systems operate under real conditions.
Begin with the problem, concern or target you need to understand. The scope discussion can identify which systems and evidence should be reviewed first.
The agreed scope may include mechanical and electrical plant, distribution systems, operating conditions, controls, energy information, maintenance records, measurements and site observations. The exact content depends on the building and client objectives.
Yes. The audit can focus on a defined concern such as high energy use, poor heating, plant cycling or repeated faults. The scope may be widened where connected systems appear relevant to the cause.
Relevant BMS settings, schedules, alarms, overrides and trend information may be reviewed where controls affect the systems being investigated. A separate, deeper BMS audit may be recommended for complex control issues.
No. Testing is selected according to the building, systems, access, available information and agreed scope. The aim is to gather useful evidence without including unnecessary work.
Yes. Recommendations can distinguish operational corrections, maintenance actions, further investigation, remedial works and longer-term capital improvements.
Useful information may include drawings, BMS access, asset lists, energy data, maintenance records, service reports, previous surveys and details of known operating concerns.
Tell us about the building, systems, operating concern, energy issue or planned investment you want reviewed. We can then discuss an appropriate audit scope.
Independent building performance, M&E, BMS, biomass and FM audits. HandoverPoint Audits is the specialist building-performance division of the HandoverPoint Network.
INSPECT. ANALYSE. IMPROVE.
© 2026 HandoverPoint. All rights reserved. HandoverPoint Audits is part of the HandoverPoint Network, a trading brand of HVAC Ireland.
Privacy Policy – Cookie Notice – Terms & Conditions – Accessibility Notice